| 10-305 |
ARR, 3 phase, Silicon Controlled Rectifiers |
|
130 Volt three phase chargers, * Enter 'G' for 208 Vac, 'H' for 240 Vac
and 'K' for 480 Vac. Consult Application Engineering before quoting
other than 480 Vac for pricing. |
| ARR130* 50 |
ARR rectifier, 50 amperes, Unfiltered |
| ARR130* 50F |
ARR rectifier, 50 amperes, Filtered to 100 mV w/ battery |
| ARR130* 75 |
ARR rectifier, 75 amperes, Unfiltered |
| ARR130* 75F |
ARR rectifier, 75 amperes, Filtered to 100 mV w/battery |
| ARR130* 100 |
ARR rectifier, 100 amperes, Unfiltered |
| ARR130* 100F |
ARR rectifier, 100 amperes, Filtered to 100 mV w/battery |
| ARR130* 150 |
ARR rectifier, 150 amperes, Unfiltered |
| ARR130* 150F |
ARR rectifier, 150 amperes, Filtered to 100 mV w/battery |
| ARR130* 200 |
ARR rectifier, 200 amperes, Unfiltered |
| ARR130* 200F |
ARR rectifier, 200 amperes, Filtered to 100 mV w/battery |
| ARR130K 300 |
ARR rectifier, 300 amperes, Unfiltered |
| ARR130K 300F |
ARR rectifier, 300 amperes, Filtered to 100 mV w/battery |
| ARR130K 400 |
ARR rectifier, 400 amperes, Unfiltered |
| ARR130K 400F |
ARR rectifier, 400 amperes, Filtered to 100 mV w/battery |
| ARR130K 500F |
ARR rectifier, 400 amperes, Filtered to 100 mV w/battery |
|
|
|
260 Vdc three phase chargers |
| ARR260* 25 |
ARR rectifier, 25 amperes, Unfiltered |
| ARR260* 25F |
ARR rectifier, 25 amperes, Filtered to 100 mV w/battery |
| ARR260* 50 |
ARR rectifier, 50 amperes, Unfiltered |
| ARR260* 50F |
ARR rectifier, 50 amperes, Filtered to 100 mV w/battery |
| ARR260K 100 |
ARR rectifier, 100 amperes, Unfiltered |
|
|
|
260 Vdc three phase chargers |
| ARR260K 100F |
ARR rectifier, 100 amperes, Filtered to 100 mV w/battery |
| ARR260K 150 |
ARR rectifier, 150 amperes, Unfiltered |
| ARR260K 150F |
ARR rectifier, 150 amperes, Filtered to 100 mV w/battery |
| ARR260K 200 |
ARR rectifier, 200 amperes, Unfiltered |
| ARR260K 200F |
ARR rectifier, 200 amperes, Filtered to 100 mV w/battery |
|
|
|
ARR (4623) cabinet options for: ARR 130vdc 50-150amp & ARR 260 Vdc
25-50amp chargers. |
|
Insert Systems DC Voltage in place of xx in part number. |
|
High/Low Voltage Alarm Options: Insert Systems DC Voltage in place of xx
in part number. (130 or 260 Vdc) |
| MBC04759-xx |
High/Low Voltage Alarm Relay |
| MBC04759-xxL |
High/Low Voltage Alarm Relay w/2 Lights |
| MBC04756-xx |
Low DC Voltage Alarm Relay w/Time Delay |
| MBC04756-xxL |
Low DC Voltage Alarm Relay w/Time Delay & Light |
| MBC04755-xx |
High DC Voltage Alarm Relay w/Time Delay |
| MBC04755-xxL |
High DC Voltage Alarm Relay w/Time Delay & Light |
|
|
|
No Charge Alarm Options: Insert Systems DC Voltage in place of xx in
part number. |
| MBC04742-xx |
NCA Relay w/Loadshare Circuitry |
| MBC04742-xxL |
No Charge Alarm Light (Must order MBC04742-xx) |
|
|
|
Ground Detection Options: Insert Systems DC Voltage in place of xx in
part number. |
| KBC05856 |
Ground Detection Relay (DPDT)Double Pole Double Throw |
| KBC05856-XXL |
Ground Detection Relay (DPDT) w/ Light Double Pole Double Throw |
| KBC04635-xx |
Ground Lights w/Push-button Switch |
| KBC04638 |
Ground Switch on Voltmeter |
|
|
|
Timer Option: Timer includes equalize light and pushbutton. |
| KBC05606 |
0-255hr Auto Equalize timer E/W Light and Pushbutton |
|
|
|
Miscellaneous Options: Insert Systems DC Voltage in place of xx in part
number. |
| MBC04908-xx |
Summary Alarm Relay |
| JA02844 |
Lightning Arrestor |
| KBC03084X4 |
Drip Top for cabinet |
| KBC05485 |
Blocking Diode 50-100 amp |
| KBC04773 |
Blocking Diode 150 amp |
|
|
|
Special Breaker ratings |
| SFT00007B |
Special Wiring (SIS) Flame retardant. |
| SFT00008 |
Special Wiring (Brady Marker ID). (Must order SIS Option) |
| SFT00009 |
Special Input Voltage |
| SFT00015 |
Fungus Protection for ARR rectifiers |
| KBC04640-xx |
AC Fail Light |
|
|
|
ARR (2391) cabinet options for: ARR 130 Vdc 200amp chargers and
ARR260*100. Insert Systems DC Voltage in place of xx in part number. |
|
High/Low Voltage Alarm Options: Insert Systems DC Voltage in place of xx
in part number. |
| MBC03826-xx |
High/Low Voltage Alarm Relay |
| KBC04890-xx |
Add 2 lamps to MBC03826-xx, Must order MBC03826. |
| MBC04052-130 |
Low DC Voltage Alarm Relay |
| KBC04132-130 |
Light for Low Voltage Alarm (Must order MBC04052-130) |
| MBC04298-130 |
High DC Voltage Alarm Relay |
| KBC04260-130 |
Light for High voltage alarm (must order MBC04298-130) |
|
|
|
No Charge Alarm Options: Insert Systems DC Voltage in place of xx in
part number. |
| MBC03947-xx |
NCA Relay w/Loadshare Circuitry |
| KBC04741-xx |
No Charge Alarm Light (Must order MBC03947-xx) |
|
|
|
Ground Detection Options: Insert Systems DC Voltage in place of xx in
part number. |
| MBC05857-XX |
Ground Detection Relay (DPDT)Double Pole Double Throw |
| MBC05857-XXL |
Ground Detection Relay (DPDT) w/ Light Double Pole Double Throw |
| KBC03970 |
Ground Lights w/Push-button Switch |
| KBC03969 |
Ground Switch on Voltmeter |
|
|
|
Timer Option: Timer includes equalize light and pushbutton. |
| KBC05606 |
0-255hr Auto Equalize timer E/W Light and Pushbutton |
|
|
|
Miscellaneous Options: Insert Systems DC Voltage in place of xx in part
number. |
| NBC02457 |
Summary Alarm Relay |
| JS00478 |
Lightning Arrestor |
| MBC05646X4 |
Drip Top for cabinet |
| KBC04773 |
Blocking Diode 200 amp |
|
|
|
Special Breaker ratings |
| SFT00007B |
Special Wiring (SIS) Flame retardant. |
| SFT00008 |
Special Wiring (Brady Marker ID) (Must order SIS Option) |
| SFT00009 |
Special Input Voltage |
| SFT00015 |
Fungus Protection for ARR rectifiers |
| KBC04264-xx |
AC Fail Light |
|
|
|
ARR (2970) cabinet options for: ARR 130vdc 300-400amp & ARR 260vdc
150-200amp chargers. |
|
Insert Systems DC Voltage in place of xx in part number. |
|
High/Low Voltage Alarm options: Insert Systems DC Voltage in place of xx
in part number. |
| MBC04111-xx |
High/Low Voltage Alarm Relay |
| KBC04740-xx |
Add 2 Lamps to MBC04111. (Must order MBC04111) |
| MBC04895-xx |
Low DC Voltage Alarm Relay w/Time Delay |
| MBC04895-xxL |
Low DC Voltage Alarm Relay w/Time Delay & Light |
| MBC04896-xx |
High DC Voltage Alarm Relay w/Time Delay |
| MBC04896-xxL |
High DC Voltage Alarm Relay w/Time Delay & Light |
|
|
|
No Charge Alarm Options: Insert Systems DC Voltage in place of xx in
part number. |
| MBC04898-xx |
NCA Relay w/Loadshare Circuitry |
| MBC04898-xxL |
NCA Relay w/Light & Loadshare Circuitry |
|
|
|
Ground Detection Options: Insert Systems DC Voltage in place of xx in
part number. |
| KBC05858-XXL |
Ground Detection Relay (DPDT) 130 Vdc, 300-400 amperes or 260 Vdc,
150-200 amp |
| KBC05858-XXL |
Ground Relay (DPDT) w/Light 130 Vdc, 300-400 amperes or 260 Vdc, 150-200
amp |
| KBC03969 |
Ground Switch on Voltmeter |
| KBC03970 |
Ground Lights w/Push-button Switch |
|
|
|
Timer Option: Timer includes equalize light and pushbutton. |
| KBC05606 |
0-255hr Auto Equalize timer E/W Light and Pushbutton |
|
|
|
Miscellaneous Options: Insert Systems DC Voltage in place of xx in part
number. |
| NBC02457 |
Summary Alarm Relay |
| JS00478 |
Lightning Arrestor |
| KBC05642X4 |
Drip Top for cabinet |
| JA02388 |
Blocking Diode 300 amp |
| JA02139 |
Blocking Diode 400 amp |
|
|
|
Special Breaker ratings |
| SFT00007B |
Special Wiring (SIS) Flame retardant. |
| SFT00008 |
Special Wiring (Brady Marker ID) (Must order SIS option) |
| SFT00009 |
Special Input Voltage |
| 1% Ammeter |
One-percent accuracy ammeter |
| 1% Voltmeter |
One-percent accuracy voltmeter |