ACM 1800
 
 
10-945 The ACM 1800 Power Plant (PDS 4191) 
PDS 4191 is a +24 Vdc, 150 to 1,800 ADC system which features modular Rectifiers, distribution, and a digital meter and alarm panel.   Equipped with low-voltage disconnect.
 
Basic Plant Configurations for 150-ampere Rectifiers
110-4191L-1A PDS 4191, List 1 includes 23" X 7' relay rack, front-accessible, +24Vdc distribution bay mounted in a 23" by 7' relay rack.  E/W  battery charge bus, ground charge bus, ground return bus, two rectifier shelves, digital meter, and 36 standard breaker posit
110-4191L-2A PDS 4191, List 2 includes 23" X 7' relay rack, front-accessible, +24Vdc distribution bay mounted in a 23" by 7' relay rack.  E/W  battery charge bus, ground charge bus, ground return bus, three rectifier shelves, digital meter, and 36 standard breaker pos
110-4191L-3A PDS 4191, List 3 includes 23" X 7' relay rack, front-accessible, +24Vdc distribution bay mounted in a 23" by 7' relay rack.  E/W  battery charge bus, ground charge bus, ground return bus, one rectifier shelf, digital meter, and 36 standard breaker positio
 
Distribution Options
385-4191-00 Hardware and wiring for Group C with 18 additional 5 to 100 ampere type AM1 +24V breaker positions. 
385-4191-01 Hardware and wiring for Group D with 18 additional 5 to 100 ampere type AM1 +24V breaker positions. 
385-4191-02 Hardware and wiring for Group E with 10 additional 5 to 60 ampere type AM1 +24V breaker positions. (Rated at 80A Maximum)
385-4191-03 Hardware and wiring for Group E with 10 each 0.18 to 10 ampere GMT +24V or -48V fuse positions. (Rated for 30 Amps max.)
385-4191-04 Hardware and wiring for Group C with 4 each 150 to 400 ampere type GJ1 +24V breaker positions. 
385-4191-05 Hardware and wiring for Group D with 4 each 150 to 400 ampere type GJ1 +24V breaker positions. 
385-4191-06 Hardware and wiring for Group F with 4 each 150 to 400 ampere type GJ1 +24V breaker positions. 
385-4191-07 Hardware and wiring for Group E with 10 additional 5 to 60 ampere type AM1 -48V breaker positions. (Rated at 80A Maximum)
385-4191-15 Tempertaure Compensation Option : 1 Ambient and 3 remote sensing probes
385-4191-20 Hardware and wiring for Group E or F with 40 each 0.18 to 10 ampere GMT +24V or -48V fuse positions. (Rated for 50 Amps max.)
 
Modular Rectifiers
100-7520-24 HFM24BC150 rectifier 24V, 150A (208/240 VAC Only)
 
Field Upgrade Kits
385-4191-11 Upgrade kit to 1200A for use with List-3 plant to add shelf in the second position
385-4191-10 Upgrade kit to 1800A  for use with List-1 plant to add shelf in the third position
 
Modular Converters
385-4191-25 Modular 24 to 48 Vdc converter, 20 amperes, includes one  60 Amp breaker for converter input
385-4191-24 Modular 24 to 48 Vdc converter, 10 amperes, includes one  40 Amp breaker for converter input
385-4191-22 80 AMP Shelf for modular 20 Amp DC to DC converters
385-5668-00 40 AMP Shelf for modular 10 Amp DC to DC  converters
 
Plug-In Bullet Breakers : 100 - 450 AMPS
274-3830-05 AM1 Circuit Breaker Kit 5 ampere, 1 breaker position
274-3830-10 AM1 Circuit Breaker Kit 10 ampere, 1 breaker position
274-3830-20 AM1 Circuit Breaker Kit 20 ampere, 1 breaker position
274-3830-30 AM1 Circuit Breaker Kit 30 ampere, 1 breaker position
274-3830-40 AM1 Circuit Breaker Kit 40 ampere, 1 breaker position
274-3830-50 AM1 Circuit Breaker Kit 50 ampere, 1 breaker position
274-3830-60 AM1 Circuit Breaker Kit 60 ampere, 1 breaker position
274-3830-70 AM1 Circuit Breaker Kit 70 ampere, 2 breaker positions
274-3830-80 AM1 Circuit Breaker Kit 80 ampere, 2 breaker positions
274-3830-90 AM1 Circuit Breaker Kit 100 ampere, 2 breaker positions
274-3830-100 AM1 Circuit Breaker Kit 125 ampere, 2 breaker positions
 
Bolt-In Breakers : 5 - 225 AMPS
274-3833-100 GJ1 Circuit Breaker Kit 100 ampere, 1 breaker positions
274-3833-125 GJ1 Circuit Breaker Kit 125 ampere, 1 breaker positions
274-3833-150 GJ1 Circuit Breaker Kit 150 ampere, 1 breaker positions
274-3833-175 GJ1 Circuit Breaker Kit 175 ampere, 1 breaker positions
274-3833-225 GJ1 Circuit Breaker Kit 225 ampere, 1 breaker positions
274-3833-250 GJ1 Circuit Breaker Kit 250 ampere, 1 breaker positions
274-3833-300 GJ1 Circuit Breaker Kit 300 ampere, 2 breaker positions
274-3833-350 GJ1 Circuit Breaker Kit 350 ampere, 2 breaker positions
274-3833-400 GJ1 Circuit Breaker Kit 400 ampere, 2 breaker positions
274-3833-450 GJ1 Circuit Breaker Kit 450 ampere, 2 breaker positions
 
GMT Fuses : .18 - 10 AMPS
276-0002-00 GMT Fuse, dummy
280-0720-00 GMT Fuse 0.18 ampere
280-0730-00 GMT Fuse 0.25 ampere
280-0700-00 GMT Fuse 0.5 ampere
280-0705-00 GMT Fuse 0.75 ampere
280-0710-00 GMT Fuse 1 ampere
280-0715-00 GMT Fuse 1.33 ampere
280-0735-00 GMT Fuse 2 ampere
280-0760-00 GMT Fuse 3 ampere
280-0740-00 GMT Fuse 5 ampere
280-0750-00 GMT Fuse 7.5 ampere
280-0770-00 GMT Fuse 10 ampere

 

<< BACK

 

 

Battery USA
Your Partner for DC & Battery Power Needs

Home | Company Profile | Search Products | Professional Services | Contacts | Career Opportunities

Copyright© 2006 - Battery USA :: All Rights Reserved