6 BTS
6BTS  
+24VDC power plant supplies 150 to 1200 Adc (maximum) load distribution utilizing standard 23" racks.
The plant features modular switched-mode rectifiers, digital meter and alarm, and battery temperature compensation.  
The plant is available in 14 differ
 
110-4102-01A 6BTS ACM 1200 600A without 1200A LVD, LVBD, and Load shedding, E/W 1 rectifier shelf and  72 breaker positions 
110-4102-02A 6BTS ACM 1200 600A with single LVD, without Load shedding (Disconnects both busses), E/W 1 rectifier shelf and 72 breaker positions 
110-4102-03A 6BTS ACM 1200 600A with single LVD Load shedding contactor (Disconnects right 36 positions only), E/W 1 rectifier shelf and 72 breaker positions
110-4102-04A 6BTS ACM 1200 600A with single LVD contactor (disconnects both busses) and 1200A loadshedding contactor (disconnects right bus), E/W 1 rectifier shelf and 72 breaker positions
110-4102-05A 6BTS ACM 1200 600A with single LVBD (disconnects both busses from battery only), E/W 1 rectifier shelf and 72 breaker positions
110-4102-06A 6BTS ACM 1200 600A with 1200A LVBD contactor (disconnects both busses from battery only) and 1200A loadshedding contactor (disconnects right bus only), E/W 1 rectifier shelf and 72 breaker positions
110-4102-07A 6BTS ACM 1200 600A with dual LVD (disconnects either bus), E/W 1 rectifier shelf and 72 breaker positions
110-4102-08A 6BTS ACM 1200 same as List 1 except  E/W 2 rectifier shelves and 72 breaker positions
110-4102-09A 6BTS ACM 1200 same as List 2 except  E/W 2 rectifier shelves and 72 breaker positions
110-4102-10A 6BTS ACM 1200 same as List 3 except  E/W 2 rectifier shelves and 72 breaker positions
110-4102-11A 6BTS ACM 1200 same as List 4 except  E/W 2 rectifier shelves and 72 breaker positions
110-4102-12A 6BTS ACM 1200 same as List 5 except  E/W 2 rectifier shelves and 72 breaker positions
110-4102-13A 6BTS ACM 1200 same as List 6 except  E/W 2 rectifier shelves and 72 breaker positions
110-4102-14A 6BTS ACM 1200 same as List 7 except  E/W 2 rectifier shelves and 72 breaker positions
 
Modular Rectifier Options
100-7520-24 HFM24BC150 rectifier 24V, 150A (208/240 VAC Only)
 
Optional Equipment
385-5761-01 6BTS DC/DC Converter Shelf allows up to 5, 3A 24/48V converters includes a 10 position distribution for individual GMT fuses. (Fuses, breakers, and converters not included)
385-5761-02 6BTS DC/DC Converter Shelf allows up to 5, 3A 24/48V converters includes a 10 position snap-in circuit breaker distribution.(Fuses, breakers, and converters not included)
385-5762-01 24V GMT fuse distribution includes a 10 position distribution with individual GMT fuses. (Fuses not included)
106-4080-00 +24 Vdc to -48 Vdc, 3 A DC to DC Converter Module with fan
385-5763-01 6BTS Front Access AC Wiring for 600A systems 
385-5763-02 6BTS Front Access AC Wiring for 1200A systems 
385-5759-00 Upgrade Kit from 600A to 1200A
 
AM1 Circuit Breakers - For Load Distribution
271-0160-40 AM1 Snap In Type, 1 AMP Circuit Breaker - 1 breaker position
271-0160-50 AM1 Snap In Type, 3 AMP Circuit Breaker - 1 breaker position
271-0161-00 AM1 Snap In Type, 5 AMP Circuit Breaker - 1 breaker position
271-0162-00 AM1 Snap In Type, 10 AMP Circuit Breaker - 1 breaker position
271-0163-00 AM1 Snap In Type, 20 AMP Circuit Breaker - 1 breaker position
271-0160-00 AM1 Snap In Type, 25 AMP Circuit Breaker - 1 breaker position
271-0164-00 AM1 Snap In Type, 30 AMP Circuit Breaker - 1 breaker position
271-0165-00 AM1 Snap In Type, 40 AMP Circuit Breaker - 1 breaker position
271-0166-00 AM1 Snap In Type, 50 AMP Circuit Breaker - 1 breaker position
274-3798-60 AM1 Snap In Type, 60 AMP Circuit Breaker - 2 breaker positions, E/W bus bar adapter
274-3798-70 AM1 Snap In Type, 70 AMP Circuit Breaker - 2 breaker positions, E/W bus bar adapter
274-3798-80 AM1 Snap In Type, 80 AMP Circuit Breaker - 2 breaker positions, E/W bus bar adapter
274-3798-90 AM1 Snap In Type, 90 AMP Circuit Breaker - 2 breaker positions, E/W bus bar adapter
274-3798-100 AM1 Snap In Type, 100 AMP Circuit Breaker - 2 breaker positions, E/W bus bar adapter
274-3798-125 AM1 Snap In Type, 125 AMP Circuit Breaker - 3 breaker positions, E/W bus bar adapter
 
Battery Disconnect Circuit Breaker Assemblies
111-3882-00 Use with the 200A power plants provides 250A circuit breaker
111-3883-00 Use with the 600A power plants provides 750A circuit breaker
111-3884-00 Use with the 1200A power plants provides 1200A circuit breaker
 
GMT Fuses : .5 - 10 AMPS
280-0700-00 GMT Fuse 0.5   Amp  
280-0705-00 GMT Fuse 0.75 Amp 
280-0710-00 GMT Fuse 1.0   Amp 
280-0715-00 GMT Fuse 1.33 Amp 
280-0720-00 GMT Fuse 0.18 Amp 
280-0730-00 GMT Fuse 0.25 Amp 
280-0735-00 GMT Fuse 2.0   Amp 
280-0740-00 GMT Fuse 5.0   Amp 
280-0750-00 GMT Fuse 7.5   Amp 
280-0760-00 GMT Fuse 3.0   Amp 
280-0770-00 GMT Fuse 10.0 Amp 

 